Quvvat transformatori 20/110 kV, 40 MVA, ONAN

Yuqori ishonchlilikka ega 110/20 kV, 40 MVA ONAN quvvat transformatori, IEC 60076 talablariga mos. Mis chulg‘amlar, vakuum OLTC, to‘liq monitoring va barcha aksessuarlar bilan.

Power Transformer 20/110KV, 40MVA, ONAN

Applicated Reference

Wind power Station​

PV Power Station

Generator Factory

Island

Large-scale
Industrial User

TEXNIK MA’LUMOT VARAQASI 1d — Uch fazali transformator 110/20 kV, 40 MVA

№ Texnik parametrlar O‘lchov birligi Talab qiymati Taklif qiymati
Ishlab chiqaruvchi / Turi / Kod / Versiya
— Ishlab chiqaruvchi —
— Turi / Kod / Versiya —
1. Iqlimiy va ekspluatatsion sharoitlar
1.1 O‘rnatish joyi — Ochiq havoda (outdoor) —
1.2 Maks. balandlik m maks. 1000 —
1.3 Havo harorati (maks / min) °C +45 / -35 —
1.4 20 °C da nisbiy namlik % 100 —
1.5 Seysmik tezlanish m/s² 0.2 —
1.6 Shamol bosimi daN/m² 70 —
1.7 Maks. quyosh radiatsiyasi kW/m² 1.3 —
2. Konstruktsiya talablari
2.1 Magnit o‘zak materiali — Sovuq prokatlangan kremniyli po‘lat listlar —
2.2 Chulg‘am materiali — Mis —
2.3 Izolyatsion moy markasi — Nynas —
2.3.1 Dielektrik yo‘qotish koeffitsiyenti (tgδ) 90 °C da (IEC 60247) % < 0.5 —
2.3.2 Moydagi suv miqdori (EN 60814) ppm < 10 —
2.3.3 Ishlovsiz sinish kuchlanishi (EN 60156) kV > 70 —
2.4 Vtulkalar (bushing)da tgδ o‘lchash rozetkalari — Ha —
2.5 Sovitish usuli — ONAN —
2.6 Himoya qoplamalari (ichki/tashqi, qalinlik, yopishish, mahkamlagichlar) — Ichki: moyga chidamli emal; Tashqi: grunt + 2 qatlam; ≥80 μm; yopishish 1–2; galvanizli mahkamlagichlar —
3. Texnik xarakteristikalar
3.1 Yuklamasiz kuchlanish nisbatlari kV/kV 110/20 110/20
3.2 Nominal quvvat MVA 40/40 40/40
3.3 110 kV tomonda yuklama ostida rostlagich (OLTC) — 19 pog‘ona (1 / 10 / 19) % / kV ±9 × 1.78; 127.62 / 110 / 92.378 Xuddi shunday
3.4 Vektor guruhi — Yod-11 Yod-11
3.5 Nominal chastota Hz 50 50
3.6 Samaradorlik indeksi % Min. 99.724 Min. 99.72
3.8 Yuklamasiz tok % Maks. 0.5 Maks. 0.5
3.9 Qisqa tutashuv kuchlanishi (In, fn, chulg‘am 75 °C) % 11.5 11.5
3.10 Chidash kuchlanishlari (50 Hz 1 daq / LI 1.2/50 μs) — birlamchi / ikkilamchi kV AC: 185 / 50 — LI: 450 / 125 Xuddi shunday
3.11 Izolyatsiya sinfi — A A
3.12 Chulg‘am haroratining maksimal ko‘tarilishi °C 60 60
3.13 Moy haroratining maksimal ko‘tarilishi °C 55 55
3.14 Minimal oqim yo‘li (creepage) — 110 kV / 20 kV vtulkalar mm ≥3000 / ≥600 Xuddi shunday
3.15 Shovqin darajasi dB Maks. 60 Maks. 60
3.16 Og‘irliklar (jami / maks. ko‘tarish / montajda / moy / maks. tashish) t — ≈69 / ≈45 / ≈40 / ≈19 / ≈45
4. Aksessuarlar
4.1–4.6 Magnitli moy sathi indikatori; havo filtri; OLTC; bosimni tushirish klapani; chulg‘am termometri; moy termometri — Talabga muvofiq Talabga muvofiq
4.8 Rostlagich privodi — Talabga muvofiq Talabga muvofiq
5. Xizmat ko‘rsatish va ishonchlilik
5.1 Ko‘rik (inspeksiya) oralig‘i — EP Conference 116/94 Talabga muvofiq
5.2 Kafolatlangan xizmat muddati yil 30 30
6. Sinovlar
6.1 Tip sinovlar — SR EN 60076 bo‘yicha Talabga muvofiq
6.2 Zavod (rutina) sinovlari — SR EN 60076 bo‘yicha Talabga muvofiq
7. Taqdim etiladigan hujjatlar
7.1–7.4 Texnik pasport; partiya sinov hisobotlari; tip sinov hisoboti; muvofiqlik deklaratsiyasi (kafolat va sifat sertifikatlari bilan) Ha/Yo‘q Ha Ha
8. Kafolat
8.1 Ishga tushirilganidan boshlab oy 60 24+36

TEXNIK VARAQ №2 — Magnitli moy sathi indikatori

№ Texnik parametrlar O‘lchov birligi Talab qiymati Taklif qiymati
Ishlab chiqaruvchi: Xitoy TOP-3 (tafsilotlar NDA’dan keyin ProfiCircle tomonidan beriladi). Turi/Kod/Versiya: —
1. Iqlimiy va ekspluatatsion
1.1 O‘rnatish joyi — Ochiq havoda Ochiq havoda
1.2 Maks. balandlik m maks. 1000 maks. 1000
1.3 Havo harorati (maks / min) °C +40 / -35 +45 / -35
1.4 20 °C da nisbiy namlik % 100 100
1.5 Seysmik tezlanish m/s² 0.2 0.2
1.6 Shamol bosimi daN/m² 70 70
1.7 Maks. quyosh radiatsiyasi kW/m² 1.3 1.3
2. Konstruktsiya talablari
2.1 Kommutatsiya kontaktlari Ha/Yo‘q Ha Ha
2.2 Magnit ulanish Ha/Yo‘q Ha Ha
2.3 UVga chidamli laminatsiyalangan ko‘rish oynasi Ha/Yo‘q Ha Ha
2.4 Min/Maks sath signal kontaktlari Ha/Yo‘q Ha Ha
3. Xizmat va ishonchlilik
3.1 Ko‘rik oralig‘i — EP Conference 116/94 EP Conference 116/94
3.2 Kafolatlangan xizmat muddati yil 30 30
4. Sinovlar
4.1 Tip sinovlar — Mahsulot standarti bo‘yicha Talabga muvofiq
4.2 Zavod sinovlari — Mahsulot standarti bo‘yicha Talabga muvofiq
5. Hujjatlar
5.1–5.4 Texnik pasport; partiya sinov hisoboti; tip sinov hisoboti; muvofiqlik deklaratsiyasi (kafolat va sifat sertifikati bilan) Ha/Yo‘q Ha Ha
6. Kafolat
6.1 Ishga tushirilganidan boshlab oy 60 24+36

TEXNIK VARAQ №3 — Transformator havo filtri

№ Texnik parametrlar O‘lchov birligi Talab qiymati Taklif qiymati
Ishlab chiqaruvchi / Turi / Kod / Versiya
1. Iqlimiy va ekspluatatsion
1.1 O‘rnatish joyi — Ochiq havoda Ochiq havoda
1.2 Maks. balandlik m maks. 1000 maks. 1000
1.3 Havo harorati (maks / min) °C +80 / -50 +45 / -35
1.4–1.7 Namlik / Seysmika / Shamol / Quyosh radiatsiyasi — 100% / 0.2 m/s² / 70 daN/m² / 1.3 kW/m² Xuddi shunday
2. Konstruktsiya talablari
2.1 Zanglamaydigan po‘lat filtr Ha/Yo‘q Ha Ha
2.2 Modulli namlik va harorat datchigi Ha/Yo‘q Ha Ha
2.3 Gigroskopik to‘ldirgich — Silikagel Silikagel
2.4–2.6 Test tugmasi / LED indikatsiya / Filtr qizdirishi Ha/Yo‘q Ha / Ha / Ha Ha / Ha / Ha
3. Texnik xarakteristikalar
3.1 UVga chidamli tashqi qismlar Ha/Yo‘q Ha Ha
3.2 Himoya darajasi (EN 60529) IP 55 55
3.3 Analog sath signali mA 4…20 4…20
3.4–3.6 Davriy ko‘riklar / Silikagel almashtirish / Atrof-muhit ifloslanishi — Minimal / Yo‘q / Yo‘q Minimal / Yo‘q / Yo‘q
4–7. Xizmat, sinov, hujjatlar, kafolat
4.1–4.2 Ko‘rik oralig‘i / Xizmat muddati yil 1 / 30 1 / 30
5.1–5.2 Tip / zavod sinovlari (SR EN 60076) — Talabga muvofiq Talabga muvofiq
6.1–6.4 Hujjatlar: Texnik pasport; partiya hisoboti; tip sinov hisoboti; muvofiqlik deklaratsiyasi + kafolat va sifat Ha/Yo‘q Ha Ha
7.1 Ishga tushirilganidan boshlab kafolat oy 60 60

TEXNIK VARAQ №4 — Yuklama ostida rostlagich (vakuum OLTC)

№ Texnik parametrlar O‘lchov birligi Talab qiymati Taklif qiymati
Ishlab chiqaruvchi / Turi: Vakuum rostlagich
1. Konstruktsiya
1.1 Kommutatsiya muhiti — Vakuum Vakuum
1.2 Moy harorati diapazoni °C -25…+105 -25…+105
2. Texnik xarakteristikalar
2.1 Ish pozitsiyalari soni dona 19 19
2.2 Joylashuvi — Transformator bakining ichida Bak ichida
2.3 Fazalar soni dona 3 3
2.4 Nominal tok A 250 400
2.5 Nominal sinov toki kA 4 4
2.6 Pik sinov toki kA 10 10
2.7 Maks. qisqa tutashuv davomiyligi s 3 3
2.8 Chastota Hz 50 50
2.9 Tizimning eng yuqori kuchlanishi kV Maks. 123 72.5
2.10 Yashin impulsi bo‘yicha chidash (1.2/50 μs) kV 650 325
2.11 Quvvat chastotasi bo‘yicha chidash 50 Hz / 1 daq kV 275 140
3–6. Xizmat, sinov, hujjatlar, kafolat
3.1–3.4 Kafolatlangan kommutatsiyalar / Xizmat muddati / Xizmat oralig‘i / Umr davomida — 600,000 / 30 yil / 300,000 kommutatsiya / — 600,000 / 30 yil / 200,000 kommutatsiya / ✔
4.1–4.2 Tip va zavod sinovlari (SR EN 60076) — Talabga muvofiq Talabga muvofiq
5.1–5.4 Hujjatlar: Texnik pasport; partiya hisoboti; tip sinov hisoboti; muvofiqlik deklaratsiyasi + kafolat va sifat Ha/Yo‘q Ha Ha
6.1 Ishga tushirilganidan boshlab kafolat oy 60 60

TEXNIK VARAQ №5 — Bosimni tushirish klapani

№ Texnik parametrlar O‘lchov birligi Talab qiymati Taklif qiymati
1. Iqlimiy va ekspluatatsion
1.1 O‘rnatish — Tashqi, transformator ustida Tashqi, transformator ustida
1.2 Maks. balandlik m maks. 1000 maks. 1000
1.3 Havo harorati (maks/min) °C +80 / -40 +45 / -35
1.4 Moy harorati (maks/min) °C +120 / -30 +120 / -30
1.5–1.8 Namlik / Seysmika / Shamol / Quyosh radiatsiyasi — 100% / 0.2 / 70 / 1.3 Xuddi shunday
2. Konstruktsiya
2.1 Materiallar (bo‘yalgan Al RAL7033 / zanglamas po‘lat) Ha/Yo‘q Ha / Ha Ha / Ha
2.2 Mikro-kontaktlar dona 1 NO + 1 NC 1 NO + 1 NC
3. Texnik xarakteristikalar
3.1 Uzluksiz ish toki A 10 10 (AC)
3.2 Nominal izolyatsiya kuchlanishi kV·r.m.s. 2.5 2.5
3.3 Moy harorati diapazoni °C -30…+120 -30…+120
3.4 Ish bosimi bar 0.55 0.55
4–7. Xizmat, sinov, hujjatlar, kafolat
4.1–4.2 Ko‘rik oralig‘i / Xizmat muddati — EP Conf. 116/94 / 30 yil Talabga muvofiq / 30 yil
5.1–5.2 Tip / zavod sinovlari (SR EN 60076) — Talabga muvofiq Talabga muvofiq
6.1–6.4 Hujjatlar: Texnik pasport; partiya hisobotlari; tip sinov hisoboti; muvofiqlik deklaratsiyasi + kafolat va sifat Ha/Yo‘q Ha Ha
7.1 Ishga tushirilganidan boshlab kafolat oy 60 60

TEXNIK VARAQ №6 — Moy / chulg‘am haroratini o‘lchash to‘plami

№ Texnik parametrlar O‘lchov birligi Talab qiymati Taklif qiymati
1. Iqlimiy va ekspluatatsion
1.1–1.7 Ochiq havoda; balandlik ≤1000 m; +45/-35 °C; RH 100%; seysmika 0.2; shamol 70 daN/m²; quyosh 1.3 kW/m² — Ko‘rsatilganidek Xuddi shunday
2. Tarkibiy qismlar
2.1–2.7 PT100 zond; transformator ustida analog indikator; qarshilik uzatkich; ≥4 kontakt; UV-filtrli laminat oynacha; masofaviy ko‘rsatish Ha/Yo‘q Ha Ha
3. Texnik xarakteristikalar
3.1 O‘lchash diapazoni °C -20…+140 -20…+140
3.2–3.6 Analog chiqish 4–20 mA; masofaviy ko‘rsatish; muhit kompensatsiyasi; tok kirishi (chulg‘am termometri); 4–20 mA chiqishlar quvvatlanishi Ha/Yo‘q Ha Ha
3.7 Qayta kalibrlash talab qilinadi Ha/Yo‘q Ha —
3.8 Kam texnik xizmat Ha/Yo‘q Ha Ha
4–7. Xizmat, sinov, hujjatlar, kafolat
4.1–4.2 Ko‘rik oralig‘i / Xizmat muddati — EP Conf. 116/94 / 30 yil Talabga muvofiq / —
5.1–5.2 Tip / zavod sinovlari (SR EN 60076) — Talabga muvofiq Talabga muvofiq
6.1–6.4 Hujjatlar: Texnik pasport; partiya va tip sinov hisobotlari; muvofiqlik deklaratsiyasi Ha/Yo‘q Ha Ha
7.1 Ishga tushirilganidan boshlab kafolat oy 60 60

TEXNIK VARAQ №7 — Rostlagich privodi (aktuator)

№ Texnik parametrlar O‘lchov birligi Talab qiymati Taklif qiymati
1. Iqlimiy va ekspluatatsion
1.1–1.7 Ichki yoki tashqi; balandlik ≤1000 m; +45/-35 °C; RH 100%; seysmika 0.2; shamol 70 daN/m²; quyosh 1.3 kW/m² — Ko‘rsatilganidek Ochiq havoda / Xuddi shunday
2. Konstruktsiya
2.1 Alyuminiy shkaf va eshiklar Ha/Yo‘q Ha Ha
2.2 Himoya darajasi IP 65 65
2.3 Kondensatsiyaga qarshi dizayn Ha/Yo‘q Ha Ha
3. Texnik xususiyatlar
3.1 Reduktor nisbati — 6.5 6.5
3.2 Ta’minot kuchlanishi VAC 230/400 230/400
3.3 Chastota Hz 50 50
3.4 Pog‘ona indikatsiyasi — BCD + 1–19 (NO kontaktlar) BCD + 1–19 (NO kontaktlar)
3.5 19 ta kontakt pozitsiyasini ko‘rsatish Ha/Yo‘q Ha Ha
3.6 Uzatish mexanizmi — Mustahkam V-kamarlar Mustahkam V-kamarlar
3.7 Ketma-ket kommutatsiyadan himoya — Boshqaruv zanjirida faol komponentlar orqali elektromexanik blokirovka; yordamchi zanjirlardagi yechimlar ruxsat etilmaydi Mos
4–7. Xizmat, sinov, hujjatlar, kafolat
4.1–4.4 Ko‘riklar / Kafolatlangan kommutatsiyalar / Xizmat muddati / MTBF — EP Conf. 116/94 / 600,000 / 30 yil / — Xuddi shunday / 600,000 / 30 yil / yiliga 3
5.1–5.2 Tip va zavod sinovlari (SR EN 60076) — Talabga muvofiq Talabga muvofiq
6.1–6.4 Hujjatlar: Texnik pasport; partiya hisoboti; tip sinov hisoboti; muvofiqlik deklaratsiyasi + kafolat va sifat Ha/Yo‘q Ha Ha
7.1 Ishga tushirilganidan boshlab kafolat oy 60 60

Eslatma: Maket chop etish va PDF eksport uchun tayyorlangan. Kerak bo‘lsa, sahifa raqamlari hamda header/footer qo‘shib beraman.

Asosiy afzalliklar

Yuqori xavfsizlik

  • Ishonchli va uzoq muddatli ishlash uchun ilg‘or izolyatsiya tizimlari.
  • Ortiqcha yuklama va qisqa tutashuvdan himoya qiluvchi integratsiyalashgan relelar.
  • Atrof-muhit xavflarini kamaytirish uchun yong‘inga chidamli va moy o‘tkazmaydigan (oil-tight) opsiyalar.
  • IEC / IEEE xavfsizlik standartlariga to‘liq mos.

Mustahkamlik

  • Ochiq havoda qo‘llash uchun korroziyaga qarshi qoplamali bardoshli dizayn.
  • Optimallashtirilgan sovitish tizimlari (ONAN / ONAF / KNAN) turli yuklamalarda barqaror ishlashni ta’minlaydi.
  • Minimal texnik xizmat bilan 25+ yil xizmat muddati uchun mo‘ljallangan.
  • Ekstremal ob-havo va tarmoq sharoitlarida ishonchliligi tasdiqlangan.

Yuqori integratsiya

  • BESS va qayta tiklanuvchi energiya loyihalari uchun sozlanadigan kuchlanish nisbatlari bilan ixcham o‘lchamlar.
  • Plug-and-play ulanishlar o‘rnatish va commissioning jarayonini soddalashtiradi.
  • Moslashuvchan variantlar: moyli (oil-immersed) yoki quruq (dry-type) transformatorlar.
  • O‘rta kuchlanish taqsimotidan utility miqyosidagi loyihalargacha kengaytiriladigan yechimlar.

Butun dunyoga yetkazib beramiz

Uskunalarni dunyoning istalgan nuqtasiga yetkazib beramiz.

Thank You!

Our manager will contact you shortly.