Industrial Battery Energy Storage 261kWh E7-IC.261

Industrial Battery Energy Storage 261kWh E7-IC.261

Applicated Reference

Wind power Station​

PV Power Station

Generator Factory

Island

Large-scale
Industrial User

Highly-efficient

  • High energy density, support transportation with pre-assembled batteries

Safe & reliable

  • Multiplex battery protection system that quarantees safety
  • - Interfaces reserved for arid and backup power supply that protect important loads

    from blackout

Smart & user-friendly

  • Real-time status monitoring and fault recording
  • Multi-energy coupling with PV, ESS, diesel-generator and city grid that enables wider range of application

System Parameter

Item Specification
Size 1045 × 1360 × 2326.5 mm
Communication RS485, LAN
IP Grade IP54
FPS Perfluorohexanone, aerosol, composite detector
Operation Temp. Range −20 ~ 55 ℃ (Derating required above 45 ℃)
Allowable Humidity 0–95% (Non-condensing)
Allowable Altitude ≤ 2000 m (Derating required above 2000 m)
Warranty 5 / 10 years
Cycle life 8000 times

Precautions

Safety Precautions

  • Be sure to have professional electrical personnel or trained and qualified technicians to operate.
  • Ensure that the high-voltage power switch is disconnected during installation.
  • Please check the material carefully before installation. If it is missing or damaged, do not proceed with installation.
  • Insulation gloves must be worn during installation, and the outside of metal tools must be tightly wrapped with insulation tape before use.
  • It is strictly prohibited to touch the total positive and total negative of the battery pack at the same time during installation to avoid high voltage injuries.
  • Non-professionals are prohibited from disassembling the module shell, and are not allowed to touch the internal circuit board to avoid electric shock accidents.
  • Without confirmation by the manufacturer’s technical personnel, it is forbidden to modify or use this system on other projects to avoid serious accidents.

Safe Use Guide

  • Guarantee measures shall be provided for the safe and reliable operation environment of the battery system.
  • During use, the power must not exceed the rated power. The system should be kept away from fire, heat, and water sources. If the battery leaks or emits a peculiar smell, stop using it immediately and notify the relevant personnel for handling.
  • The battery system shall be fully charged and fully discharged every six months. It is recommended to use a charge/discharge rate of 0.5C and keep detailed records.
  • Before operating the energy storage battery after long-term storage, a safety inspection of the system must be carried out to avoid equipment damage or safety problems caused by loose connections, condensation, rust, or mold.

Statement of Responsibility

The specification is for reference only. Please consult our company for any matters not mentioned in this specification.
When the version of this specification is updated, our company will not provide further notice.
The specific parameters of the system at the time of supply shall be subject to the signed technical agreement.